Chimney fan Corten model
chimney fan High voltage cable The high-voltage cable connecting a Gemi chimney fan unit to its speed controller must withstand continuous exposure to flue gas temperatures at the fan end while remaining flexible enough at the controller end for neat wall installation. Gemi Elettronica supplies… Read more
chimney fan High voltage cable
The high-voltage cable connecting a Gemi chimney fan unit to its speed controller must withstand continuous exposure to flue gas temperatures at the fan end while remaining flexible enough at the controller end for neat wall installation. Gemi Elettronica supplies heat-resistant cables rated to the maximum operating temperature of each fan model, cut to standard lengths covering the full range of residential and commercial chimney stack heights. Gemi replacement cables are available in standard lengths and to custom order for non-standard stack heights. Order direct from the manufacturer for factory pricing, UK delivery in 24–48h and confirmation of the correct cable specification for your fan model.
Temperature rating by fan model
The basic galvanised chimney fan operates at a maximum flue gas temperature of 300°C, requiring a cable rated to at least this temperature at the fan end junction. The professional AISI 304, copper and Corten models are rated for 700°C continuous operation — the temperature experienced at the fan housing during a flue fire — and require the higher-specification cable supplied with those models. Using a 300°C cable on a 700°C-rated fan voids the manufacturer's guarantee and creates a fire risk at the cable entry point.
Cable routing options
Gemi cables can be routed externally down the chimney stack face using stainless steel cable clips spaced at 500 mm intervals, or internally through the flue using the liner gap in a twin-wall insulated liner installation. External routing is the standard approach for single-wall clay flue and masonry chimney installations; internal routing is used where planning restrictions require no visible external cabling on a listed or conservation-area building.
Standard lengths and cut-to-order supply
Cables are supplied in standard lengths of 5 m, 10 m and 15 m to cover the most common stack heights from two-storey to tall Victorian terrace chimneys. Longer lengths are available to order. The cable is supplied with pre-fitted fan-end terminations compatible with all current Gemi fan models.
UK delivery 24–48h — factory direct
Order replacement or additional cable direct from Gemi Elettronica. Factory pricing, UK delivery in 24–48h.